Can You Use Vinegar to Clean a CPAP Humidifier?

Learn when diluted white vinegar can clean a CPAP humidifier chamber, how to rinse and dry it safely, and why your device manual should guide the process.

By Caleb Bennett Reviewed by Dr. Irene Medical review dateJan 21, 2026 9 min read

Yes, diluted white vinegar can clean some removable CPAP humidifier chambers and help remove mineral deposits, but only if your device’s instructions allow it. The correct dilution and soaking time depend on your machine. Never pour vinegar into the CPAP machine itself or run it through the airflow system. After cleaning, rinse the chamber thoroughly with clean water and let it dry completely before using it again.

Why is vinegar used to clean a CPAP humidifier?

A continuous positive airway pressure (CPAP) machine may have a humidifier chamber that holds water to add moisture to the air delivered during sleep. Over time, minerals in the water can leave white or chalky deposits on the chamber's inner surfaces. These deposits are often called limescale.

White household vinegar is an acidic liquid that can help loosen mineral buildup. Some CPAP manufacturers and hospital sleep services recommend it as an option for cleaning a removable water chamber, particularly when limescale has collected. However, vinegar is not required for every cleaning session, and the method should match the instructions for your particular device.

For example, University Hospitals Sussex NHS Foundation Trust advises that white vinegar can help remove limescale and debris from the water chamber and stresses that the chamber must be rinsed thoroughly before use.

How do you clean a CPAP humidifier with vinegar?

First, check the cleaning instructions supplied with your CPAP machine. They identify which parts can be removed, which cleaning products are allowed, and how long each part can be soaked. If vinegar is approved for your humidifier chamber, follow these steps.

  1. Turn off and unplug the machine. Disconnect it from the electrical supply before cleaning. If the humidifier has been heating water, allow it to cool before removing the chamber.
  2. Remove the water chamber. Follow the manufacturer's instructions to detach it safely. Empty any remaining water and separate the chamber's parts only if the design allows it.
  3. Prepare the approved cleaning solution. Use plain white household vinegar and water in the proportion specified in your device manual. Do not assume that every CPAP chamber uses the same mixture.
  4. Soak only for the recommended time. Place the permitted removable components in the solution or fill the chamber as directed. Follow the device-specific soaking instructions rather than extending the time to remove stubborn deposits.
  5. Rinse the chamber thoroughly. Empty the solution and rinse all treated surfaces with clean, drinking-quality water. Repeat as needed to remove vinegar residue and its smell.
  6. Allow the chamber to dry completely. Place it on a clean surface and let it air-dry away from direct sunlight. Reassemble it only when the parts are dry and undamaged.

According to ResMed's CPAP cleaning guidance, one approved option for its humidifier tub is a solution of one part vinegar to nine parts room-temperature water, followed by a thorough rinse with warm, drinking-quality water. This is an example for the equipment covered by that guidance, not a universal recipe for every CPAP machine.

What vinegar-to-water ratio should you use?

There is no single dilution that applies to every CPAP humidifier. Some product instructions specify a diluted vinegar solution, while other devices may recommend mild soap for routine cleaning and vinegar only for mineral deposits. The materials and design of the chamber can affect which cleaning methods are appropriate.

Do not use undiluted vinegar or choose a stronger mixture simply because the deposits are difficult to remove unless the manufacturer specifically instructs you to do so. A solution that is appropriate for one model may not be suitable for another. If your manual does not mention vinegar, contact the equipment manufacturer or your CPAP supplier before using it.

Can vinegar damage a CPAP machine?

Vinegar may be suitable for some removable humidifier chambers, but that does not mean it is safe for the entire CPAP system. The humidifier chamber, machine housing, heating plate, electrical components, tubing and filters have different cleaning requirements.

SleepApnea.org's CPAP cleaning guidance advises against running vinegar through the CPAP machine itself. It also distinguishes removable components from parts, such as reusable filters, that should not be cleaned with vinegar unless the device's instructions specifically permit that method.

To avoid damaging your equipment:

  • Never add vinegar to the water used for your normal overnight CPAP treatment.
  • Do not run vinegar through the machine, heating system or airflow pathway.
  • Do not immerse the electronic machine or humidifier base in water or cleaning solution.
  • Do not soak the mask, tubing, seals or filters in vinegar unless their own cleaning instructions allow it.
  • Avoid bleach, alcohol, scented oils, harsh chemicals and unapproved descaling products that may damage equipment or leave unwanted residue.

Using the wrong cleaning method may affect the equipment's condition or performance. Cleveland Clinic's CPAP cleaning guidance emphasizes checking the manufacturer's instructions, disconnecting the components before cleaning, rinsing them properly and allowing them to dry away from direct sunlight.

How often should you clean the humidifier chamber?

Daily care and deeper cleaning serve different purposes. For many CPAP systems, the usual routine is to empty the chamber after use, clean or wipe it according to the instructions, and allow it to dry. More thorough washing is often recommended weekly, while vinegar may be reserved for periodic mineral removal or used on the schedule specified by the manufacturer.

A practical routine is to:

  • Every day: Empty leftover water, follow the device's daily cleaning instructions and allow the chamber to dry.
  • On the recommended cleaning day: Wash the permitted parts with mild, fragrance-free detergent and water, or use another method specifically approved for your model.
  • When mineral deposits appear: Use a vinegar solution only if the manufacturer permits it, following the specified dilution, soaking time and rinsing instructions.

Cleaning schedules differ between devices, so follow your own user manual rather than automatically applying a schedule intended for another brand. Use fresh water for each treatment session and follow the water-quality recommendations supplied with your equipment.

What if white deposits remain after cleaning?

If white deposits remain, check that you used the correct solution and soaking time for your chamber. Do not scrape the surface with sharp tools or use an unapproved commercial descaler to speed up the process. If your manual permits gentle brushing, use only the type of brush it recommends.

Inspect the chamber after cleaning. Cracks, leaks, persistent cloudiness, pitting or other visible deterioration may mean that the chamber needs replacing rather than further soaking. Ask your equipment supplier or manufacturer about replacement if the chamber remains damaged or cannot be cleaned using the approved method.

When should you ask your CPAP supplier for advice?

Contact your equipment supplier or the device manufacturer if you cannot find cleaning instructions, are unsure whether vinegar is allowed, or notice damage after cleaning. They can confirm the appropriate method for your exact model. If vinegar has accidentally entered the machine's electronic housing or airflow system, do not continue cleaning or operate the device until you have obtained model-specific guidance.

The main principle is simple: vinegar can be a useful option for removing mineral deposits from certain CPAP humidifier chambers, but it should never replace the manufacturer's cleaning instructions. The correct solution, careful rinsing and complete drying help protect both your equipment and your normal treatment routine.

Frequently Asked Questions

Common questions about using vinegar to clean a CPAP humidifier chamber.

Can I use apple cider vinegar instead of white vinegar?

Plain white household vinegar is the type specified in many CPAP cleaning instructions. Do not substitute apple cider vinegar or another cleaning product unless the manufacturer confirms that it is suitable for your device.

How long should I soak a CPAP water chamber in vinegar?

The soaking time depends on the device. Follow the duration in your CPAP manual and avoid leaving the chamber in vinegar longer than recommended. Rinse it thoroughly and let it dry completely before using it again.

Can I put vinegar in my CPAP humidifier and run the machine?

No. Vinegar should not be added to the water used during normal treatment or run through the CPAP machine. If approved, it is used only to clean specified removable parts, which must be rinsed thoroughly before reuse.

Is vinegar better than soap for cleaning a CPAP humidifier?

Not necessarily. Mild soap and water are commonly recommended for routine cleaning, while a vinegar solution may help remove mineral deposits. The best method depends on your device's instructions and whether you are removing everyday residue or limescale.

Can I use my CPAP humidifier if the chamber still smells of vinegar?

Do not use the chamber until it has been rinsed thoroughly and dried as directed. If a vinegar smell remains, rinse it again with clean water. If the smell persists despite proper rinsing, contact your equipment supplier before using the chamber.